logo
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Zhongshan Hobun Electric & Gas Appliances Co., Ltd.
Home ProductsForced Exhaust Gas Water Heater

Forced Exhaust Gas Water Heater Featuring LED Display and Product Size 560350140 MM Suitable for Commercial

China Zhongshan Hobun Electric & Gas Appliances Co., Ltd. certification
China Zhongshan Hobun Electric & Gas Appliances Co., Ltd. certification
I'm Online Chat Now

Forced Exhaust Gas Water Heater Featuring LED Display and Product Size 560350140 MM Suitable for Commercial

Forced Exhaust Gas Water Heater Featuring LED Display and Product Size 560350140 MM Suitable for Commercial
Forced Exhaust Gas Water Heater Featuring LED Display and Product Size 560350140 MM Suitable for Commercial Forced Exhaust Gas Water Heater Featuring LED Display and Product Size 560350140 MM Suitable for Commercial

Large Image :  Forced Exhaust Gas Water Heater Featuring LED Display and Product Size 560350140 MM Suitable for Commercial

Product Details:
Brand Name: HAOBANG
Certification: CE
Payment & Shipping Terms:
Minimum Order Quantity: 100 Pcs
Price: 90 USD
Packaging Details: Plastic Film To Cover The Product, Foam Board To Support The Outer Box
Delivery Time: 30 Days
Supply Ability: 500,000 Pcs/year
Detailed Product Description
Flue Dimension: 50MM / 60MM / 90MM Product Size: 560*350*140 MM
Protection: Optional Heat Exchanger: Oxygen Free Copper
Temperature Control Range: 35-80 Degree Venting Type: Forced Exhaust
Installation Location: Kitchen / Balcony Ignition Type: Electronic Ignition
Highlight:

Forced exhaust gas water heater with LED display

,

Commercial forced exhaust gas water heater

,

Forced exhaust gas water heater 560x350x140mm

Description


When it comes to your family's safety, compromise is not an option. The Family Safety Guardian 10L Instant Gas Water Heater represents the culmination of decades of safety engineering, incorporating multiple redundant protection systems that work tirelessly to prevent accidents before they can occur. Every component, from the oxygen-free copper heat exchanger to the electronic control board, has been selected and tested with family welfare as the paramount consideration. This is not merely a water heater, it is a comprehensive safety system that happens to provide endless hot water.



Technical Parameters:

Water Flow Rate 2.64 GPM
Heat Exchanger Oxygen Free Copper
Warranty 1 Year
Flue Dimension 50MM / 60MM / 90MM
Heat Input 21kW
Product Size 560*350*140 MM
Capacity 10 Liters Per Minute
Gas Type Natural Gas
Display LED
Temperature Control Range 35-80 Degree
 

Specifications


The safety architecture begins with the flame failure protection system, which continuously monitors burner presence through advanced ionization detection. Should the flame extinguish for any reason, gas flow ceases within 0.3 seconds, preventing accumulation of unburned fuel. The overheat protection engages at precisely 176 degrees Fahrenheit, utilizing both electronic sensors and a mechanical backup system. The IPX2 waterproof rating ensures safe operation in humid bathroom environments where electrical components might otherwise be compromised.



Applications


This safety-focused design is essential for families with young children, elderly residents, or individuals with reduced temperature sensitivity. It is the recommended choice for households where children may independently operate shower controls, as the precise temperature maintenance prevents scalding incidents. Landlords and property managers specify this model for rental properties to minimize liability exposure. Healthcare facilities and assisted living centers appreciate the multiple safety redundancies for vulnerable populations.



Feature


The defining feature is the triple-redundant temperature monitoring system. Three independent thermistors continuously measure water temperature at different points in the heat exchange path. The primary sensor controls normal operation, while secondary and tertiary sensors provide backup verification. If any sensor detects temperature exceeding safe thresholds, or if sensors disagree beyond acceptable variance, the system immediately enters safe shutdown mode. This approach eliminates single points of failure that could lead to dangerous overheating.



Competitive Advantage


While competing products offer basic flame failure protection, few provide the comprehensive safety ecosystem found in this unit. The combination of ionization flame detection, dual overheat protection, dry-burn prevention, and forced exhaust monitoring creates a safety net that exceeds industry standards. Insurance providers in several jurisdictions offer premium discounts for properties equipped with this level of gas appliance safety, recognizing the reduced risk profile.



Amazing Effects


Parents describe a profound sense of relief knowing that their children can shower independently without risk of scalding. The consistent temperature eliminates the shock of unexpected hot water surges, making bathing more comfortable for elderly users with sensitive skin. Caregivers appreciate the audible alerts that signal operational anomalies, allowing prompt attention before situations escalate.



Mechanism of Action


Safety monitoring operates continuously, even when the heater is not actively heating water. The control board performs self-diagnostics every few seconds, testing sensor functionality, valve integrity, and fan operation. Upon water flow detection, the system executes a pre-ignition safety checklist, verifying exhaust fan operation, checking for proper gas pressure, and confirming sensor calibration. Only when all parameters meet safety criteria will ignition proceed. During operation, the system monitors hundreds of data points per minute, ready to execute protective shutdown if any parameter deviates from safe ranges.



Applicable for Ingredients


The ionization flame sensor utilizes a platinum-coated electrode resistant to corrosion from combustion byproducts. Overheat protection incorporates a bimetallic strip manufactured from specialized alloys that maintain consistent response characteristics across thousands of thermal cycles. The control board features conformal coating that protects sensitive electronics from humidity and condensation. Safety relays are rated for 100,000 operations, ensuring reliable performance throughout the product lifespan.



Not Applicable for


This unit cannot replace proper household safety equipment such as carbon monoxide detectors or smoke alarms. It is not designed for installation by uncertified individuals, regardless of technical skill. Use in applications where safety systems might be deliberately bypassed is strictly prohibited. The unit cannot compensate for inadequate building ventilation or improper exhaust installation.



Cautions


Never disable or bypass any safety feature, regardless of operational inconvenience. Test the flame failure system annually by observing shutdown behavior when gas supply is interrupted. Replace the unit if any safety system shows signs of malfunction, even if heating performance appears normal. Install carbon monoxide detectors in accordance with local regulations, as this heater supplements but does not replace such protection. Educate all household members on emergency gas shutoff procedures.



Benefits of Energy Optimization


The safety systems contribute to efficiency by preventing wasteful overheating and ensuring complete combustion. The flame failure protection eliminates gas waste from extinguished pilots, a common source of inefficiency in older systems. Precise temperature control prevents the energy waste associated with excessively hot water that must be mixed down to usable temperatures.



Active Ingredients


Primary flame ionization sensor with platinum electrode. Secondary thermistor overheat protection at 176°F. Tertiary bimetallic strip backup overheat protection. Forced exhaust fan with tachometer verification. Water pressure stabilization valve. Dry-burn prevention flow sensor. Emergency gas shutoff solenoid valve.



Effects


Families report significantly reduced anxiety about gas appliance safety. The reliable operation eliminates the need for constant monitoring or supervision during use. Children develop independence in personal hygiene with parental confidence in safety protection. Elderly users enjoy comfortable bathing without fear of temperature-related injuries.



Product Attention


Schedule annual safety inspections with certified technicians who can verify proper operation of all protective systems. Maintain records of inspections and any maintenance performed. Replace safety components only with factory-authorized parts to ensure proper function. Test emergency shutoff procedures quarterly with all household members. Report any unusual odors, sounds, or behaviors immediately to qualified service personnel.



Not Applicable For


Not suitable for DIY installation regardless of homeowner experience. Cannot be used with modified or non-standard gas supplies. Not appropriate for installations where regular professional maintenance cannot be assured. Not designed for use by individuals unable to understand or respond to warning indicators.

Contact Details
Zhongshan Hobun Electric & Gas Appliances Co., Ltd.

Contact Person: Mr. Kevin

Tel: 13432164812

Send your inquiry directly to us (0 / 3000)