Summer Winter Mode Support Switch Flame Failure Protection Safety Features and Oxygen Free Copper Heat Exchanger Forced Exhaust Gas Water Heater
forced exhaust gas water heater with flame failure protection
,oxygen free copper heat exchanger water heater
,summer winter mode gas water heater
Summer Winter Mode Support Switch Flame Failure Protection Safety Features and Oxygen Free Copper Heat Exchanger Forced Exhaust Gas Water Heater
Product Description
Salt-laden coastal air attacks appliances in ways that inland installations never experience — accelerating corrosion on exposed metal, degrading electrical contacts, and shortening the service life of components that would last decades a hundred kilometres further from the sea. Our 10L Instant Constant Temperature Gas Water Heater is specified with these conditions in mind. The plate iron housing carries a protective coating available in the buyer's chosen colour, the IPX2 waterproof classification guards internal components against the persistent humidity of seaside utility spaces, and the oxygen-free copper heat exchanger brings inherent corrosion resistance to the wetted surfaces where failure most often begins. Delivering 21kW of heat output with ±0.5°C temperature stability, it performs to specification in an environment that punishes shortcuts.
Specifications
The 530-by-330-by-143-millimetre plate iron enclosure combines with IPX2 sealing to resist the airborne moisture typical of coastal service balconies. Thermal efficiency remains above 93 percent, and natural gas at 2000 pascals enters through a G1/2 inch connection at a rate of 2.06 cubic metres per hour under full demand. The system produces 11 litres per minute at a 25-degree Celsius rise, equal to 2.64 gallons per minute. Working water pressure spans 0.02 to 0.8 pascals — relevant in coastal towns where municipal supply can vary with seasonal tourist demand. Touch-panel temperature control ranges from 35 to 80 degrees Celsius, electronic ignition avoids the corrosion-prone components of older pilot systems, and 220V forced exhaust venting supports 50, 60, and 90 millimetre flue diameters.
Technical Parameters
| Dimensions | Varies By Model |
| Ignition Method | Electronic Ignition |
| Exhaust | Forced Exhaust |
| Origin | Guangdong, China |
| Gas Pressure | NG (2000Pa) |
| Water Flow Rate | 2.64 GPM |
| Free Spare Part | Offer 1% According To The Total QTY |
| Safety Features | Flame Failure Protection, Overheat Protection |
| Loading Quantity 40HQ | 780 PCS |
| Flue Dimension | 50MM / 60MM / 90MM |
Installation Scenarios & Installation Precautions
Coastal holiday cottages, seaside boutique homestays, marina staff quarters, and beachfront serviced apartments all present the salt-air conditions this configuration is intended for. Wherever possible, install on an interior-facing wall of an enclosed service balcony rather than an exterior-facing surface directly exposed to onshore wind. Verify the wall structure, then establish 200 millimetres of top clearance and 150 millimetres on each side. Route the flue so the terminal faces away from prevailing sea wind if the building layout permits, and maintain the mandatory 600-millimetre separation from windows, doors, and air intakes. Complete a soapy-water leak inspection on every gas joint. Never install in a sealed bathroom or unventilated cupboard, where trapped humid air would accelerate internal corrosion even faster than open coastal exposure.
Features & Value Delivered to Global Buyers
The technical package covers ±0.5°C constant temperature output, flame failure protection, overheat protection at 176 degrees Fahrenheit, electronic ignition, and LED touch-panel display. What sets this unit apart from budget alternatives in coastal deployment is corrosion strategy — oxygen-free copper wetted surfaces rather than plated aluminium, a coated plate iron shell in any specified colour, and IPX2 sealing verified rather than claimed. Efficiency above 93 percent and 780-piece 40HQ container loading round out the commercial case. OEM buyers can specify silk-screen branding, colour, flue diameter, display type, and supplementary protection modules, with a one-year warranty, one percent free spare parts, and complete documentation included as standard.
Safety Boundaries & Long-Term Use Reminders
This unit is not designed for direct outdoor exposure to rain and sea spray without a protective enclosure, not suitable for unheated locations subject to freezing without freeze-protection accessories, and cannot be converted to alternative fuel types without factory authorisation. During use, avoid spraying water directly onto the control panel, never obstruct the flue outlet, and educate all occupants on emergency gas shutoff. Coastal maintenance intervals should be shortened relative to inland norms: wipe the exterior housing with fresh water and dry it thoroughly every month to remove salt deposits, inspect electrical connections annually for corrosion, and replace flexible gas hoses and sealing gaskets on schedule rather than waiting for visible deterioration.
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.