Temperature Range 35°C-65°C Flue Gas Water Heater With Wall Hanging Installation and 84 Percent Efficiency Designed for Operation
Flue gas water heater with wall hanging
,Flue gas water heater 35°C-65°C range
,Flue gas water heater 84 percent efficiency
Temperature Range 35°C-65°C Flue Gas Water Heater With Wall Hanging Installation and 84 Percent Efficiency Designed for Operation
Product Description
The everyday kitchen deserves an everyday hero — a hot water source that just works, morning after morning, without demanding attention or complicated setup. Our 10L Flue Type Instant Gas Water Heater fills exactly that role, mounting quietly on a kitchen wall and springing to life within 3 to 5 seconds of any tap opening downstream. The 20-kilowatt burner is generously sized for a 10-litre-per-minute flow, which comfortably handles a stack of greasy dinner dishes, a large stockpot rinse, and a subsequent shower without the flame ever faltering. The digital display shows current outlet temperature at a glance, while the water-gas interlock valve intelligently modulates the burner as flow changes, so you never need to hunt for the right tap balance between hot and cold.
Specifications
The chassis measures 590 by 340 by 180 millimetres, slim enough to sit above a countertop without overwhelming the kitchen skyline. A harmonica-shape triple burner sits at the heart of the combustion chamber, delivering 20 kilowatts of rated heat input while maintaining a compact envelope. The oxygen-free copper heat exchanger achieves thermal efficiency above 85 percent, and heating stabilises within 15 seconds of ignition with temperature deviation held under 2 degrees Celsius. Working water pressure ranges from 0.025 to 0.8 megapascals, and the temperature knob spans 35 to 80 degrees Celsius via a digital LED display. Fuel compatibility covers both LPG at 2800 pascals and natural gas at 2000 pascals, feeding through a G1/2 inch gas connection paired with G1/2 inch water inlet and outlet threads.
Technical Parameters
| Connection Size | G1/2" (Gas/Inlet/Outlet) |
| Noise Level | Low Noise Function |
| Timer | 20Min In-built |
| Rated Gas Pressure | LPG: 2800pa / NG: 2000pa |
| Working Water Pressure | 0.025-0.8 Mpa |
| Fuel Type | Natural Gas / LPG / Coal Gas |
| Heat Exchange Material | Copper |
| Capacity | 6L |
| Installation | Wall-Hanging |
| Application | Residential, Commercial, Industrial Water Heating |
Installation Scenarios & Installation Precautions
Traditional Chinese-style kitchens, Southeast Asian wet kitchens, Latin American open cocinas, and Middle Eastern service kitchens all share the naturally ventilated layout that suits this flue-type unit perfectly. It also fits well in semi-enclosed service balconies, laundry corners with an operable window, and outdoor kitchen shelters common in warmer climates. Mount the heater on a solid masonry or reinforced framed wall at eye level so the digital display and knobs remain easy to read and reach. Reserve at least 150 millimetres of clearance on both sides for future service access, and route the 90-millimetre chimney straight up or with minimal horizontal offset to preserve natural draft. Confirm that a source of fresh combustion air, whether an open window, ventilation louvre, or door grille, is permanently available whenever the unit is running.
Features & Value Delivered to Global Buyers
The feature set is intentionally practical: low-water-pressure startup, dual ignition pins for reliable first-strike lighting, flame-failure protection, anti-dry combustion, overheat cutoff, a 20-minute timed shutdown, and a winter-summer switch that trims gas consumption during warmer months by lowering baseline heat output. Three engineering decisions define its edge over competitors: a harmonica-shape triple burner for even flame distribution, a copper heat exchanger available in weights from 0.8 to 4.0 kilograms depending on distributor preference, and a magnificently thin-shaped housing that reads as modern rather than industrial. OEM buyers can specify white-coated, glass, or stainless steel panels, and MOQ starts at 100 pieces per model with T/T 30 percent deposit standard payment terms.
Safety Boundaries & Long-Term Use Reminders
This unit must not be installed inside a bathroom or sleeping area under any circumstances — it is explicitly designed for kitchen or well-ventilated balcony placement with an outdoor flue termination. It is not compatible with sealed combustion configurations and cannot substitute for a room-sealed condensing boiler in tightly insulated modern homes. During cooking, keep splashing oil and food debris clear of the housing, and never hang tea towels or aprons on the top cover where they could contact heated surfaces. If the ignition delay ever exceeds 5 seconds noticeably, replace the DC 3V batteries and inspect the electrodes for carbon buildup. Annual professional service should include chimney inspection, burner cleaning, and verification that all four protection systems (over-pressure, anti-dry, overheat, flame-failure) trip within their designed thresholds.
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.