Rated Gas Pressure LPG 2800pa NG 2000pa Flue Gas Water Heater Industrial Water Heating Capacity 6L Energy Saving Solution
Flue Gas Water Heater LPG 2800pa
,Industrial Water Heater 6L capacity
,Energy Saving Flue Gas Heater
Rated Gas Pressure LPG 2800pa NG 2000pa Flue Gas Water Heater Industrial Water Heating Capacity 6L Energy Saving Solution
Product Description
International distributors sourcing gas water heaters face a common tension between competitive pricing and reliable technical performance — this 10L Flue Type Instant Gas Water Heater has been engineered specifically to resolve that tension in favour of both. As a manufacturer established in 1997 with dedicated production lines for gas water heaters, gas stoves, and gas boilers, we deliver a specification sheet that meets or exceeds most regional standards while maintaining the cost structure wholesalers need to build profitable retail programs. Every unit ships with the same 20-kilowatt harmonica-shape triple burner, oxygen-free copper heat exchanger, and dual-pin pulse ignition system that our domestic-market flagship carries, giving distributors a defensible technical story to tell buyers rather than a race-to-the-bottom pricing pitch.
Specifications
The physical dimensions of 590 by 340 by 180 millimetres and 8-kilogram net weight optimise both container loading and delivery vehicle handling in export markets. Packing dimensions of 670 by 405 by 230 millimetres and 9-kilogram gross weight per unit inform accurate freight calculations at the quotation stage. Rated heat input is 20 kilowatts, hot water output is 10 litres per minute at 25 degrees Celsius temperature rise, and thermal efficiency clears 85 percent through the copper heat exchanger. Water pressure compatibility spans 0.025 to 0.8 megapascals, and fuel input accommodates LPG at 2800 pascals or natural gas at 2000 pascals via standard G1/2 inch threaded connections that match plumbing conventions in most global markets.
Technical Parameters
| Ignition Type | Automatic Electronic Pulse Ignition |
| Heat Exchange Material | Copper |
| Fuel Type | Natural Gas / LPG / Coal Gas |
| Ignition Method | Battery Operated, Battery Ignition |
| Packaging Types | Corrugated Box / Color Box |
| Installation | Wall-Hanging |
| Color | All Color Will Be Available |
| Connection Size | G1/2" (Gas/Inlet/Outlet) |
| Application | Residential, Commercial, Industrial Water Heating |
| Rated Gas Pressure | LPG: 2800pa / NG: 2000pa |
Installation Scenarios & Installation Precautions
This standard OEM configuration is designed for the majority of residential markets across Latin America, the Middle East, Africa, Central Asia, and Southeast Asia where flue-type gas water heaters remain the dominant hot water solution. Typical end-user installations include kitchens, service balconies, laundry rooms, staff quarters, and small guesthouse utility zones. Distributors should ensure their downstream installer networks understand the natural-draft requirements: adequate ambient combustion air, unobstructed 90-millimetre chimney routing to an outdoor termination, and strict avoidance of sealed bathroom or bedroom installations. Regional building codes vary significantly, so distributors are advised to include local installation guidance in their retail packaging where required, and to specify accessories such as chimney extensions, wall-mounting hardware kits, and freeze-protection accessories appropriate to their served climate zones.
Features & Value Delivered to Global Buyers
Commercial terms are structured for serious wholesale partnerships: 100-piece minimum order quantity per model, 5-to-20-day sample lead time depending on customisation depth, 30-to-35-day production lead time after deposit receipt, and T/T 30 percent deposit with 70 percent balance against copy of Bill of Lading. Three engineering decisions define its edge over competitors: a genuine oxygen-free copper heat exchanger (not tinned or aluminium substitute), a high-quality pulse ignitor engineered for full one-year battery life, and OEM flexibility spanning housing colour, panel material (white coated, glass, or stainless steel), knob layout, LED or LCD display choice, and silk-screen branding. Shipping ports include Zhongshan, Guangzhou, and Shenzhen, giving distributors flexibility to consolidate with other Pearl River Delta suppliers.
Safety Boundaries & Long-Term Use Reminders
This unit is not suitable for markets requiring room-sealed or condensing boiler technology, since it is an open-flue natural-draft design. It cannot substitute for forced-exhaust units in installations without adequate natural ventilation, and distributors should not represent it as suitable for sealed bathroom installation. Prior to shipping, distributors should confirm the specified gas type (LPG or NG) and pressure match the destination market, since retrofit conversion is significantly more expensive after delivery. Include destination-appropriate installation manuals in the retail box, and consider bundling a starter set of DC 3V batteries so end users can verify operation immediately upon installation without a separate shopping trip. Warranty coverage is one year from date of manufacture, and complimentary spare-part kits should be preserved by the distributor for warranty replacement purposes.
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.