White LPG Gas Water Heater Digital Display Technology Providing Consistent Hot Water Supply for Commercial and Domestic
LPG gas water heater digital display
,commercial domestic hot water heater
,flue gas water heater consistent supply
White LPG Gas Water Heater Digital Display Technology Providing Consistent Hot Water Supply for Commercial and Domestic
Product Description
A water heater occupies visible wall space for years, so its front panel influences a room long after the installation invoice has been forgotten. This 6L flue type instant gas water heater gives importers and project buyers three practical exterior directions: clean white-coated metal for volume housing, stainless steel for service areas that need a durable finish, or glass for design-led retail ranges. The appearance changes, but the operating platform remains consistent. A 12-kilowatt harmonica-shaped burner heats water only while it is flowing, eliminating the bulk and standing heat loss of a storage cylinder. Automatic pulse ignition responds to the opening tap, and adjustable controls let the user match the 30-to-55-degree output range to seasonal inlet conditions. The compact 6-litre-per-minute format is intended for a single household outlet, while the DC 3V ignition supply allows operation without a nearby electrical socket. An oxygen-free copper heat exchanger provides the thermal core beneath every panel choice.
Specifications
The casing measures 440 by 300 by 120 millimetres, giving all three panel versions the same mounting footprint and simplifying assortment planning for distributors. Rated heat input is 12 kilowatts, nominal delivery is 6 litres per minute at a 25-degree Celsius rise, and tested thermal efficiency is no lower than 84 percent. The heater accepts inlet pressure from 0.02 to 0.8 megapascals and adjusts outlet temperature between 30 and 55 degrees Celsius. Its pulse system is powered by DC 3V batteries and works with two ignition pins for dependable lighting. LPG and natural-gas configurations are prepared separately for 2800 and 2000 pascals respectively. Three G1/2-inch ports serve the water inlet, hot outlet, and fuel connection. Combustion gases move through a 90-millimetre chimney, while optional LED or LCD indication can be matched with the chosen coated, stainless-steel, or glass front.
Technical Parameters
| Heat Exchanger Material | Copper |
| Ignition Type | Electronic Ignition |
| Chimney Size | 60mm |
| Controller | Knob Control |
| Gas Pressure | NG (2000Pa) / LPG (2800Pa) |
| Valve | Solenoid Valve |
| Installation Location | Kitchen / Balcony |
| Installation Type | Wall Mounted |
| Exhaust System | Flue Exhaust |
| Special Features | Digital Display |
Installation Scenarios & Installation Precautions
White-coated versions suit economical apartment projects and staff housing, stainless-steel models fit wet kitchens and covered utility corridors, and glass-fronted units work well in boutique homestays or renovated residences where the appliance remains visible. Finish selection does not change the ventilation requirements. Every version needs permanent replacement air and a correctly sized smoke pipe terminating outdoors, and none belongs in a sealed bathroom, bedroom, staircase, or storage room without an independent air path. Use a solid wall, preserve 200 millimetres of clear service space at the top and 150 millimetres on both sides, and keep the 90-millimetre chimney as vertical as site conditions permit. Protect coated and glass panels from direct cooking flame, corrosive cleaning chemicals, and repeated outdoor rain exposure. Test fuel connections with soap solution before commissioning and confirm that the fascia does not conceal warning labels or service access points.
Features & Value Delivered to Global Buyers
When compared side by side with generic single-finish imports, the buying advantage is range architecture rather than a cosmetic add-on. One common internal platform supports three panel materials, all-colour painting, silk-screen marks, and optional temperature displays, allowing a distributor to build good-better-best tiers without multiplying technical spare parts. The internal functions include low-pressure startup, dual-pin ignition, seasonal gas adjustment, flame-loss shutdown, dry-burn prevention, overheat protection, water-pressure protection, and a 20-minute operating limit. OEM programs start at 100 pieces per model, with sample lead times linked to decoration requirements, normal production after deposit, a one-year warranty, and free knobs, battery boxes, ignitors, thermostats, switches, or cartons for after-sales support.
Safety Boundaries & Long-Term Use Reminders
Panel choice does not convert an open-flue appliance into a sealed unit, so the heater still requires an outdoor chimney and continuous room ventilation. Do not install it in sleeping quarters, enclosed shower cubicles, or exposed exterior locations without weather protection. Keep cloths and flammable cleaning products away from the upper casing. Clean glass only with a soft non-abrasive cloth, wipe stainless steel along its grain, and avoid acidic products on coated metal. Replace ignition batteries once a year, inspect the flue terminal each season, and have a trained technician verify burner condition and protection functions during annual maintenance.
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.