Wall Mounted Gas Water Heater Heat Water Quickly Designed for Continuous in Demanding Industrial and Commercial Settings
wall mounted gas water heater
,continuous industrial gas water heater
,commercial flue gas water heater
Wall Mounted Gas Water Heater Heat Water Quickly Designed for Continuous in Demanding Industrial and Commercial Settings
Product Description
Every extra day gained from an LPG cylinder matters in homes where replacement bottles must be transported, stored, and paid for in advance. This 10L flue type instant gas water heater helps households manage that recurring cost by heating only while water flows and by providing a winter-summer control for seasonal fuel adjustment. When a tap opens, the water-gas interlock initiates DC 3V pulse ignition, two electrodes light the harmonica-shaped triple burner, and the oxygen-free copper heat exchanger begins delivering hot water without maintaining a storage tank between uses. A rated 20-kilowatt input supports approximately 10 litres per minute at a 25-degree Celsius rise, giving the unit enough output for a residential shower or washing point used one at a time. During warm months, users can reduce burner demand instead of mixing large volumes of cold water into overheated output. In colder weather, the higher setting restores the heat needed for cooler incoming water. This practical control strategy turns fuel economy into an everyday operating choice rather than an abstract efficiency claim.
Specifications
The wall-mounted cabinet measures 590 by 340 by 180 millimetres and weighs approximately 8 kilograms net, with a packed size of 670 by 405 by 230 millimetres and a gross weight near 9 kilograms. Rated thermal input reaches 20 kilowatts, while the copper heat exchanger supports efficiency of at least 85 percent. Nominal hot-water production is 10 litres per minute, or about 2.7 gallons per minute, at the specified 25-degree Celsius rise. The appliance accepts working water pressure from 0.02 to 0.8 megapascals and can initiate at approximately 0.015 megapascals under suitable flow conditions. Outlet adjustment extends from 35 to 80 degrees Celsius. LPG models require 2800 pascals and natural-gas versions 2000 pascals. DC 3V batteries power pulse ignition, all three connections use G1/2-inch threads, and combustion products leave through a 90-millimetre natural-draft chimney.
Technical Parameters
| Optional Protection | Yes |
| Function | Heat Water Quickly |
| Installation Location | Kitchen/Balcony |
| Ignition Type | Electronic Ignition |
| Heating Capacity | 10L/min |
| Color | White |
| Heat Exchanger Material | Copper |
| Use Gas Type | LPG / NG |
| Installation Type | Wall Mounted |
| Connection Size | G1/2" (Gas/Inlet/Outlet) |
Installation Scenarios & Installation Precautions
This fuel-conscious configuration suits LPG-supplied homes, traditional kitchens, ventilated service balconies, rural residences, and covered utility areas where a single major hot-water outlet is used at a time. It must be mounted outside every sealed bathroom and away from bedrooms, stairwells, or rooms without an independent combustion-air path. The 90-millimetre smoke pipe must terminate outdoors and should rise as directly as possible to protect natural draft. An openable window, fixed ventilation louvre, or door grille must replace the air consumed by combustion. Verify that the wall supports the filled appliance, leave at least 200 millimetres above the casing and 150 millimetres on both sides, and avoid terminal positions exposed to reverse pressure beneath eaves. LPG cylinders should remain outdoors with the correct regulator. Before use, test all fuel joints with soap solution and confirm battery polarity.
Features & Value Delivered to Global Buyers
The commercial value rests on operating economy, familiar controls, and serviceable construction. The winter-summer selector works alongside low-pressure startup, dual ignition pins, flame-loss shutdown, anti-dry protection, overheat control, excess-pressure protection, and a 20-minute safety limit. Buyers can specify coated steel, stainless-steel, or glass panels, select housing colours, and add silk-screen branding or optional temperature indication. MOQ begins at 100 pieces per model, samples can be prepared according to decoration needs, and regular production follows order confirmation and deposit. A one-year warranty and complimentary service parts support regional distributors after delivery.
Safety Boundaries & Long-Term Use Reminders
Fuel-saving controls do not provide automatic temperature regulation, so users must adjust settings as inlet conditions change. The heater is unsuitable for sealed bathrooms, sleeping rooms, direct rain exposure, or continuous industrial duty. Never obstruct the top cover, store combustible items nearby, or keep an LPG cylinder inside the occupied room. Close the gas valve immediately after unusual odour, delayed ignition, or persistent yellow flame. Replace the DC 3V batteries annually, clean the inlet filter every three months where sediment is common, inspect the chimney terminal for nests or debris, and arrange yearly testing of the burner and protective shutdowns.
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.