White Flue Gas Water Heater Featuring G1/2 Connection Size Ideal for Kitchen Balcony Installation Location Long Lasting

Product Specification
Brand Name: Haobang
Minimum Order Quantity: 100 Pcs
Price: 45-50 USD
Supply Ability: 500,000 Pcs/year
Product Details
Highlight:

White Flue Gas Water Heater

,

G1/2 Connection Water Heater

,

Kitchen Balcony Flue Gas Heater

Installation Location: Kitchen/Balcony
Service Provided: Free Spare Parts
Color: White
Optional Protection: Yes
Function: Heat Water Quickly
Heat Exchanger Material: Copper
Customer Customization: Yes
Water Pressure Start: 0.02Mpa-0.8Mpa
Product Description

White Flue Gas Water Heater Featuring G1/2 Connection Size Ideal for Kitchen Balcony Installation Location Long Lasting



Product Description


Heat-exchanger value should be documented in the purchase specification, not guessed from a polished front panel. This 10L flue type instant gas water heater allows professional buyers to define copper type and exchanger weight within the available model range before production. The approach helps importers build transparent good-better-best tiers while retaining one familiar installation platform. A 20-kilowatt harmonica-shaped triple burner transfers heat into the selected exchanger, supplying approximately 10 litres per minute at a 25-degree Celsius rise. Water flow activates the interlock and DC 3V pulse ignition, so fuel is consumed only during a draw rather than maintaining stored water. Mechanical controls permit adjustment from 35 to 80 degrees Celsius without implying an electronic proportional system. The same chassis can carry coated, stainless-steel, or glass panels and optional temperature indication. For distributors, specification control reduces the risk of hidden material substitution and creates a clearer technical story for different retail bands.



Specifications


The standard enclosure measures 590 by 340 by 180 millimetres and packs in a 670-by-405-by-230-millimetre carton. Typical net and gross weights are 8 and 9 kilograms, depending on panel and internal configuration. Rated heat input reaches 20 kilowatts and thermal efficiency is at least 85 percent. Buyers can select oxygen-free or tinned-copper configurations where offered, with exchanger weights available from approximately 0.8 to 4.0 kilograms according to exact model design. Nominal water output is 10 litres per minute at a 25-degree rise. Working pressure spans 0.02 to 0.8 megapascals, while low-pressure startup can occur near 0.015 megapascals. LPG units require 2800 pascals and natural-gas units 2000 pascals. DC 3V pulse ignition, G1/2-inch ports, and a 90-millimetre chimney complete the core specification.



Technical Parameters


Optional Protection Yes
Thermal Efficiency ≥85%
Rated Power 20000 W
Use Gas Type LPG / NG
Service Provided Free Spare Parts
Valve Solenoid Valve
Function Heat Water Quickly
Heat Exchanger Material Copper
Customer Customization Yes
Heating Capacity 10L/min


Installation Scenarios & Installation Precautions


Material-graded models suit wholesalers serving multiple price points, hotel or housing projects with written bills of materials, renovation contractors comparing lifecycle value, and regional dealers responding to different water conditions. Installation requirements remain identical across exchanger grades. Mount the heater in a ventilated kitchen, service balcony, or covered utility area with permanent replacement air. Route the 90-millimetre smoke pipe outdoors, predominantly upward, and never place the appliance in a sealed bathroom, bedroom, stairwell, or enclosed store. Check the supporting wall, leave 200 millimetres above and 150 millimetres on each side, and fit an inlet screen where sediment may enter. Verify fuel calibration, use approved G1/2-inch fittings, conduct a soap-solution leak test, and record the exchanger specification for future matching.



Features & Value Delivered to Global Buyers


The commercial advantage is traceable configuration. Exchanger material and weight can be linked to the order, while fascia, colour, display, printed branding, and carton create visible differentiation. Low-pressure activation, dual ignition pins, water-gas interlock, flame-failure shutdown, anti-dry protection, overheat and pressure controls, seasonal adjustment, and a 20-minute timer remain available across the platform. Standard MOQ is 100 pieces per model, samples can be inspected before volume approval, and normal production begins after deposit. A one-year warranty and free service components support the chosen specification after sale.



Safety Boundaries & Long-Term Use Reminders


Copper weight alone does not determine lifespan; water chemistry, wall thickness, workmanship, gas setup, and maintenance also matter. The unit is unsuitable without permanent ventilation and an exterior chimney, and it should not be used above 0.8 megapascals without pressure reduction. Do not advertise unsupported longevity claims based only on material mass. Keep the casing clear, respond immediately to gas odour or yellow flame, and never disable protective devices. Clean the inlet filter, descale according to local hardness, replace batteries annually, inspect the flue, and retain order records when purchasing replacements.